BB Electronics TV Converter Box MES1A MES1B User Manual

Documentation Number MES1A/B-2106qsg PN7137-rev001  
Quick Start Guide  
Check Package Content  
Configure the MES1A/B  
1
2
5
6
To change the IP Address, Default Gateway or Netmask, type 1.  
To configure Master/Slave and Serial Interface settings, type 2.  
Do not change any configuration settings in section 3.  
To configure Modbus/TCP Settings, type 4.  
To configure Modbus Master settings, type 5.  
To save your settings in the MES1A/B, type S.  
MES1A or MES1B unit  
Printed version of this MES1A/B Quick Start Guide  
Printed manual  
Software CD  
Modbus TCP to  
Modbus ASCII/RTU  
Hardware Installation  
Converters  
Connect the MES1A/B to the network using an Ethernet  
cable.  
Models: MES1A/MES1B  
Modbus Device Installation  
Connect your PC to the network.  
Connect a 12 VDC power supply (not included) to the  
MES1A/B and apply power. (10 – 30VDC, 3.6 Watts)  
Connect Modbus device to the serial interface on the  
MES1A/B using the correct cabling:  
-
MES1A is a DTE: Use a straight through serial cable if  
the Modbus device is a DCE; null modem if device is DTE  
MES1B: Four-wire for RS-422, two-wire for RS-485, Set  
RS-422/485 switch.  
-
Software Installation  
3
4
Your Modbus device should now be operational on the  
network.  
Insert the software CD. It should auto-start into the  
installation wizard.  
Follow the on screen installation wizard to install the  
Device Installer software.  
Software supports Windows 98, Me, 2K, XP, & NT 4.0  
LED Status  
7
LED  
Power  
Link  
Color/Status  
Red  
Function  
Power applied  
Bootup, 10BaseT  
100BaseT  
MES1A  
RS-232 Model  
MES1B  
RS-422/485 Model  
Orange  
Green  
Discover the MES1A/B on the network  
Activity  
Green (Blinking)  
Orange  
Data on the network  
Bootup  
Open the Device Installer software. It should detect the  
MES1A/B and display XPort in the third level of the  
Devices Tree.  
Note: The MES1A/B can be reset (rebooted) by pressing the Reset  
switch for one second. Reset switch is accessed through a small hole in  
the top of the enclosure.  
Expand the tree and click the device IP Address.  
Select the Telnet Configuration tab, then click Connect.  
Press Enter within five seconds to go into Setup Mode.  
Warning: Do not forget your password if used. There is no easy way to  
get into the unit for configuration once you forget your password.  
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA  
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland  
Documentation Number MES1A/B-2106qsg PN7137-rev001  
+353 91 792444 Fax +353 91 792445  
 

Addonics Technologies Computer Hardware ADSAUSPCB User Manual
AEG Freezer A72900GNW0 User Manual
AGFA Digital Camera DC 730i User Manual
Alpine Headphones SHS N100 User Manual
Altec Lansing MP3 Docking Station Octiv Air User Manual
American Audio DJ Equipment PPA 210 User Manual
Axis Communications Car Video System M7001 User Manual
Behringer Musical Instrument Amplifier LX110 User Manual
Behringer Stereo System XR12 User Manual
Beko Freezer CDA660F User Manual