INSTALLATION GUIDE
AXIS P7216 Video Encoder
Europe
Tel: +46 46 272 18 00
Fax: +46 46 13 61 30
This digital equipment fulfills the requirements for RF
emission according to the Class B limit of EN 55022.
This product fulfills the requirements for immunity
according to EN 61000-6-1 residential, commercial and
light-industrial environments.
This product fulfills the requirements for immunity
according to EN 61000-6-2 industrial environments.
Australia/New Zealand
This digital equipment fulfills the requirements for RF
emission according to the Class B limit of AS/NZS CISPR 22.
Japan
この装置は、クラスB 情
報技術装置です。この装
置は、家庭環境で使用することを目 的としていま
すが、この装置がラジオやテレビジョン受信機に
近接
して使用されると、 受信障害を引き起こすこ
とがあります。 取扱説明書に従って正しい取り扱
いをして下さい。
Korea
이 기기는 가정용(B급) 전자파적합기기로서 주로
가정에서 사용하는 것을 목적으로 하며, 모든 지
역에서 사용할 수 있습니다.
Safety
This product complies with IEC/EN/UL 60950-1, Safety of
Information Technology Equipment.
The power supply used with this product shall fulfill
the requirements for Safety Extra Low Voltage
(SELV) and Limited Power Source (LPS) according to
IEC/EN/UL 60950-1.
Disposal and Recycling
When this product has reached the end of its useful life,
dispose of it according to local raws and regulations. For
information about your nearest designated collection point,
contact your local authority responsible for waste disposal.
In accordance with local legislation, penalties may be
applicable for incorrect disposal of this waste.
Europe
This symbol means that the product shall not be
disposed of together with household or commercial waste.
Directive 2012/19/EU on waste electrical and electronic
equipment (WEEE) is applicable in the European Union
member states. To prevent potential harm to human health
and the environment, the product must be disposed of in
an approved and environmentally safe recycling process.
For information about your nearest designated collection
point, contact your local authority responsible for waste
disposal. Businesses should contact the product supplier for
information about how to dispose of this product correctly.
This product complies with the requirements of
Directive 2011/65/EU on the restriction of the use of
certain hazardous substances in electrical and electronic
equipment (RoHS).
China
This product complies with the requirements of the
legislative act Administration on the Control of Pollution
Caused by Electronic Information Products (ACPEIP).
Contact Information
Axis Communications AB
Emdalavägen 14
223 69 Lund
Sweden
AXIS P7216 Video Encoder
Safety Information
Read through this Installation Guide carefully before installing the product. Keep the Installation
Guide for future reference.
Hazard Levels
DANGER
WARNING
CAUTION
NOTICE
Indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
Indicates a situation which, if not avoided, could result in damage
to property.
Other Message Levels
Important
Indicates significant information which is essential for the product
to function correctly.
Note
Indicates useful information which helps in getting the most out
of the product.
5
AXIS P7216 Video Encoder
Safety Instructions
NOTICE
• The Axis product shall be used in compliance with local laws and regulations.
• To use the Axis product outdoors, or in similar environments, it shall be installed in an
approved outdoor housing.
• Store the Axis product in a dry and ventilated environment.
• Avoid exposing the Axis product to vibration, shocks or heavy pressure.
• Do not install the product on unstable or vibrating brackets, surfaces or walls.
• Use only applicable tools when installing the Axis product. Excessive force could cause
damage to the product.
• Do not use chemicals, caustic agents, or aerosol cleaners. Use a damp cloth for cleaning.
• Use only accessories that comply with technical specification of the product. These can be
provided by Axis or a third party.
• Use only spare parts provided by or recommended by Axis.
• Do not attempt to repair the product by yourself. Contact Axis support or your Axis
reseller for service matters
Transportation
NOTICE
• When transporting the Axis product, use the original packaging or equivalent to prevent
damage to the product.
Battery
The Axis product uses a 3.0 V CR2032 lithium battery as the power supply for its internal real-time
clock (RTC). Under normal conditions this battery will last for a minimum of five years.
Low battery power affects the operation of the RTC, causing it to reset at every power-up. A log
message will appear when the battery needs replacing.
The battery should not be replaced unless required, but if the battery does need replacing, contact
WARNING
• Risk of explosion if the battery is incorrectly replaced.
• Replace only with an identical battery or a battery which is recommended by Axis.
• Dispose of used batteries according to local regulations or the battery manufacturer's
instructions.
6
AXIS P7216 Video Encoder
Installation Guide
This Installation Guide provides instructions for installing AXIS P7216 Video Encoder on your
network. For other aspects of using the product, see the User Manual available at www.axis.com
Installation Steps
1. Make sure the package contents, tools and other materials necessary for the installation
are in order. See page 7 .
2. Study the hardware overview. See page 7 .
3. Study the specifications. See page 10.
4. Install the hardware. See page 13.
5. Access the product. See page 14.
Package Contents
•
•
Axis P7216 Video Encoder
Power adapter model
-
Type PS-P
•
•
Mounting kit
-
-
4 surface pads
2 brackets
Terminal connectors
-
-
4 I/O 6–pin connector
4 RS-485/422 2x2–pin connector
•
•
Installation and Management Software CD
Printed materials
-
Installation Guide (this document)
Hardware Overview
1
Power connector
7
AXIS P7216 Video Encoder
2
3
4
5
6
7
8
9
Network connector SFP
Network connector RJ45
Auxiliary connector RJ45 (maintenance)
Card slot (microSD) x4
I/O terminal connector x4
RS-485/422 connector x4
Control button x4
Protective earth
1
2
3
4
5
6
7
8
9
Video input connector BNC x16
Network LED RJ45
Network LED SFP
Network LED auxiliary
Power LED
Status LED 1–4
Audio out connector
Audio in connector 2
Audio in connector 1
LED Indicators
LED
Color
Green
Amber
Indication
Net-
work
Steady for connection to a 1 GBit/s network. Flashes for network activity.
Steady for connection to a 10/100 MBit/s network. Flashes for network
activity.
Unlit
No network connection.
Status
Power
Green
Amber
Red
Steady green for normal operation.
Steady during startup and when restoring settings.
Slow flash for failed upgrade.
Green
Amber
Normal operation.
Flashes green/amber during firmware upgrade.
8
AXIS P7216 Video Encoder
Connectors
For specifications, see page 10.
BNC connector - Each video input is terminated using a coax/BNC connector. Connect a 75 Ohm
coaxial video cable; the recommended maximum length is 800 feet (250 meters).
Note
75 Ohm video termination can be enabled/disabled for the video input via the product's
web page at Video & Audio > Video Input > Video termination. This termination is enabled
on factory default. In cases where the product is to be connected in parallel with other
equipment, for optimum video quality, it is recommended that termination be enabled for
only the last device in the video signal chain.
Network connector - RJ45 Ethernet connector.
SFP connector - The unit can only use one Network interface, either an SFP module or RJ45
connector. SFP module has higher priority than the RJ45 connector.
NOTICE
The product shall be connected using a shielded network cable (STP). All cables connecting
the product to the network switch shall be shielded (STP) and intended for their specific
use. Make sure that the network switch is properly grounded. For information about
Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is
used from a stereo signal).
Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address
(PA) system or an active speaker with a built-in amplifier. A stereo connector must be used for
audio out.
SD card slot - A standard or high-capacity microSD card (not included) can be used for local
recording with removable storage.
NOTICE
To prevent corruption of recordings, the SD card should be unmounted before removal. To
unmount, go to Setup > System Options > Storage > SD Card and click Unmount.
Control button - The control button is used for:
•
•
Resetting the product to factory default settings. See page 14.
Connecting to an AXIS Video Hosting System service or AXIS Internet Dynamic
DNS Service. For more information about these services, see the User Manual.
9
AXIS P7216 Video Encoder
Power connector - 2-pin terminal block for power input. Use a limited power source (LPS) with
either a rated output power limited to £100 W or a rated output current limited to £5 A.
I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time
lapse recording and alarm notifications. In addition to an auxiliary power and a GND pin, the I/O
terminal connector provides the interface to:
•
Digital output – For connecting external devices such as relays and LEDs.
Connected devices can be activated by the VAPIX® Application Programming
Interface, output buttons on the Live View page or by an Action Rule. The
output will show as active (shown under System Options > Ports & Devices) if
the alarm device is activated.
•
Digital input – An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass
break detectors, etc. When a signal is received the state changes and the input
becomes active (shown under System Options > Ports & Devices).
RS-485/RS-422 connector - Two 2-pin terminal blocks for RS-485/RS-422 serial interface used to
control auxiliary equipment, e.g. PTZ devices.
Specifications
Operating Conditions
The casing of AXIS P7216 is not approved for outdoor use. The product may only be installed in
indoor environments.
Product
Temperature
Humidity
AXIS P7216
0 °C to 50 °C
(32 °F to 122 °F)
20-80% RH (non-condensing)
Power Consumption
Product
Power supply
AXIS PS-P power supply
AXIS P7216
10
AXIS P7216 Video Encoder
Connectors
I/O terminal connector
6-pin terminal block for:
• Digital Input
• Digital Output
• Auxiliary power and ground
(GND)
Function
Pin Notes
Specifications
1
2
GND
Ground
3.3 V DC
Power
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Max load = 250 mA
0 to +40 V DC
3–
6
Configurable
(Input or
Output)
Digital input — Connect to GND to activate,
or leave floating (unconnected) to deactivate.
Digital output — Internal connection
to ground when activated, floating
Max load =100 mA
Max voltage = +40 V DC
(unconnected) when deactivated. If used
with an inductive load, e.g. a relay, a diode
11
AXIS P7216 Video Encoder
must be connected in parallel with the load,
for protection against voltage transients.
A
B
I/O configured as input
I/O configured as output
Power connector
DC power input
2-pin terminal block for
power input. Use a limited
power source (LPS) with
either a rated output power
limited to £100 W or a rated
output current limited to
£5 A.
Audio connector
3.5 mm audio
connectors (stereo)
12
AXIS P7216 Video Encoder
Audio Input
Audio Output
1 Tip
Microphone/Line in
Line out (mono)
2 Ring
3 Sleeve
Ground
Ground
RS-485/422 connector
Two 2-pin terminal blocks for RS485/RS422 serial
interface. The serial port can be configured to support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
• Two-wire RS422 simplex
• Four-wire RS422 full duplex point to point
communication
Function
Pin
Notes
1
RS485/RS422 RX/TX
A
(RX) For full duplex RS485/RS422
(RX/TX) For half duplex RS485
2
RS485/RS422 RX/TX
B
3
4
RS485/RS422 TX A
RS485/RS422 TX B
(TX) For full duplex RS485/RS422
Install the Hardware
Mount the video encoder
The AXIS P7216 is supplied with a mounting kit containing brackets. The unit can be mounted in
a rack or on a wall.
After removing the existing 4 screws, attach the mounting brackets to the video encoder at an
angle suitable for installation in a standard 1U 19” rack, or on the wall.
Mounting on a wall
1. Position the video encoder against the wall with the brackets attached, and mark the
four mounting holes for each bracket.
2. Drill the four mounting holes.
3. Attach the video encoder to the wall using appropriate screws.
13
AXIS P7216 Video Encoder
Connect the cables
1. Connect the video encoder to the network using a network cable RJ45 and/or a SFP cable.
2. Optionally connect the external input/output devices.
3. Optionally connect active speakers and/or external microphones.
4. Connect the cameras to the video inputs.
5. Connect the supplied indoor power adapter.
page 8
Auxiliary Connector
The AXIS P7216 is equipped with an additional RJ45 network connector. The purpose with this
connector is to simplify maintenance work on the AXIS P7216 that requires connection to a
computer.
Note
The auxiliary connector should only be connected during maintenance work.
Access the Product
Use the tools provided on the Installation and Management Software CD to assign an IP address,
set the password and access the video stream. This information is also available from the support
pages on www.axis.com/techsup/
Reset to Factory Default Settings
Important
Reset to factory default should be used with caution. A reset to factory default will reset
all settings, including the IP address, to the factory default values.
To reset the product to the factory default settings:
Note
To reset a single channel to the original factory default settings, use the button provided in
that unit’s web interface.
It is also possible to reset parameters to factory default via the web interface. Go to Setup
> System Options > Maintenance.
14
AXIS P7216 Video Encoder
Further Information
The User Manual is available at www.axis.com
product. To see the currently installed firmware version, go to Setup > About.
guides.
Warranty Information
For information about Axis’ product warranty and thereto related information, see
15
Installation Guide
Ver. M1.8
Date: May 2013
Part No. 50452
AXIS P7216 Video Encoder
© Axis Communications AB, 2013
|