Audiovox Automobile Electronics AS 9501a User Manual

INSTALLATION GUIDE FOR:  
KEYLESS ENTRY  
CHANNEL CREATOR  
WITH ADJUSTABLE TIMER  
AS-9501a  
Printed In Taiwan  
Form No. 128-4808C  
INTRODUCTION:  
The AS-9501a is a transistorized controlled "Keyless Entry Channel Creator" with an adjustable timed output of 0.8 to 60  
seconds. This versatile Keyless Controlled unit will allow the safe operation of any device that is connected to its output.  
Some of the more popular circuits that may be connected to this unit are: Remote Start, Power window roll up, Power  
sunroof close, etc. The unique feature of this unit is that a series of Remote Keyless Entry Inputs will provide an output, i.e..  
Lock, unlock, lock within 4 seconds in a two step factory configuration. This is necessary to prevent the connected device  
from accidently being activated by the in vehicle door lock switch. If this safety feature is not required or desired, than the  
unit can be set to operate from a single input.  
DIP SWITCH SETTINGS  
ON  
OFF  
1
2
POSITIVE LOCK INPUT  
2-STEP UNLOCK  
TWO WIRE  
NEGATIVE LOCK INPUT  
SINGLE STEP UNLOCK  
ONE WIRE  
POSITIVE OR NEGATIVE LOCK INPUT SELECTION : DIP SWITCH # 1  
This unit can be programmed to accept either positive or negative lock input signals. This allows for proper installation into  
vehicles using 3 wire ground, 3 wire positive, and 5 wire alternating door lock systems.  
DIP SWITCH #1: When this switch is selected to the on position, the unit will accept a positive trigger on the Orange Door  
Lock input wire. When this switch is selected to the off position, this wire will accept a negative trigger input.  
1 OR 2 WIRE UNLOCK INPUT SELECTION : DIP SWITCH # 2  
This unit can be programmed for single step, 'one wire' unlock or two-step, 'two wire' unlock configuration.  
Many OEM keyless entry systems use on-board door unlock relays, which usually results in the ability to unlock driver's door  
only and then unlock all doors.  
DIP SWITCH #2: When this switch is selected to the on position, the control circuit will operate in a two step, two wire  
configuration. This is the controlled output operation mode. When this switch is selected to the off position, the control  
circuit will operate in a single step, one wire configuration mode.  
CONFIGURATION: Two Step Factory Keyless Entry upgrade with +12 volt door locks.  
THIS INSTALLATION WILL REQUIRE THAT THE DIP SWITCHES BE SET TO 1 ON, 2 ON.  
WIRING:  
Red: +12 volt Battery Source. Connect this wire to a + 12 volt constant battery source.  
Black: Chassis Ground. Connect this wire to a clean solid metal chassis ground source in the vehicle.  
Orange: Connect this wire to the lock control wire found at the vehicle driver's door motor. This is the wire that gets +12  
volts when the door lock button on the factory keyless entry remote is depressed.  
Green: Connect this wire to the unlock control wire found at the drivers door motor. This is the wire that gets +12 volts when  
the unlock button on the factory keyless entry remote transmitter is depressed the first time.  
Blue: Connect this wire to the second unlock control wire found at any door but the driver's door. This is the wire that gets  
+12 volts when the unlock button on the factory remote transmitter is depressed two times.  
Note: This wire will not have +12 volts when the unlock button on the factory transmitter is depressed only one time.  
Light Green Wire: This wire will provide a low current ground signal when the factory keyless entry transmitter buttons are  
sequentially pressed in a Lock, Unlock, Lock pattern within 4 seconds. This wire will be connected to the trigger input of the  
device you wish to control. This output is capable of 500 mA maximum current. If the device you are connecting this wire  
to requires more than 500mA to operate, then a relay will be required. SEE FIG.# 1 for relay wiring configuration.  
The duration of the ground signal on the Light Green Wire is fully adjustable from a minimum of 0.8 seconds (800ms), to a  
maximum of 60 seconds. This adjustment is controlled by the potentiometer located through the side of the module's case.  
Turning this adjustment clockwise will increase the output duration. Turning the adjustment counter clockwise will decrease  
the output duration.  
CAUTION: This unit's potentiometer is capable of 180° rotation. DO NOT overturn this adjuster or damage will occur.  
Testing The Installation:  
In this configuration, to test your installation, press the lock, unlock, then lock buttons on the factory transmitter within a 4  
seconds time period. The accessory device should activate. Now enter the vehicle and press the in vehicle door lock switch  
in the same sequential pattern and be certain that the accessory device does not respond.  
 

3Com Cable Box 3CR856 95 User Manual
ADTRAN Network Card T200 HDSL4 User Manual
ADTRAN Server MP 114 User Manual
Agilent Technologies Stereo System 6632B User Manual
Agilent Technologies Water Dispenser 4155B User Manual
Aigo MP3 Player UM F158 User Manual
Altinex Stereo Amplifier MT108 102 User Manual
Amana Clothes Dryer ND 1 User Manual
American Standard Furnace 32 5037 01 User Manual
Avet Reels Fishing Equipment LX 46 User Manual