Installation
Instructions
DAZZLE
T028.50X
BATH AND SHOWER TRIM KITS
ff
O
ot
H
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--
please read these instructions carefully before
you begin.
Certified to comply with ANSI A112.18.1
M968834 REV 1.3
Required Tools
Flat Blade Screwdriver
Phillips Screwdriver
Channel Locks
Teflon Tape
Plumbers' Putty or Caulking
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note
roughing-in dimensions.
INLETS
1/2" NOM.
COPPER
SWEAT
INLETS
4-1/16"
SHR. 1/2" NOM.
COPPER SWEAT
SWEAT
INLETS
FINISHED WALL
1/2" NPT
2"
4-1/16"
TUB 1/2" NOM.
COPPER SWEAT
5-1/8" REF.
SWEAT
INLETS (STOPS)
1-5/8"
to
5-7/8"
3-1/4"
SHR. 1/2" NOM.
COPPER SWEAT
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
4-1/16"
7-7/8" REF.
TUB 1/2" NOM.
COPPER SWEAT
INLETS
1/2" NOM.
COPPER
SWEAT
INLETS 1/2" NPT
3-3/8"
74" FOR HEAD
CLEARANCE
7-1/8"
3-3/8"
18" OPTIONAL
OUTLETS
1/2" NPT
THREADED INLETS
1-1/2"
REF.
OUTLETS
1/2" NPT
5-7/8"
INLETS
1/2" NPT
4"
1/2" NPT
5" REF.
TOP OF TUB RIM
3-3/8"
BOTTOM OF TUB
THREADED INLETS (STOPS)
TO GAIN ACCESS TO VALVE FOR SERVICING
4
Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem.
Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON.
Remove COVER by pulling straight out.
Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.
Turn on water supply and see above for installing TRIM and HANDLE.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5).
Remove CAPS (7) and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair
Part M952100-0070A if balancing unit is defective.
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the
large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should
butt up against top of casting.
Reassemble FIXATION RING (4) and CARTRIDGE (1).
6
ROTATE 180˚
4
LARGE OUTLET
1
5
7
8
INLETS
5
3
2
9
BACK TO BACK INSTALLATION
CARE INSTRUCTIONS:
5
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968834 REV 1.3
DAZZLE
BATH AND SHOWER TRIM KITS
MODEL NUMBER
T028.50X
M962286-YYY0A
SHOWER ARM AND ESCUTCHEON
WITH SEALS
Replace the "YYY" with
appropriate finish code
M953564-YYY0A
SHOWER HEAD
CHROME
SATIN
002
295
M907051-YYY0A
CARTRIDGE CAP
078016-YYY0A
ESCUTCHEON SCREWS
M962293-YYY0A
ESCUTCHEON KIT
WITH SCREWS
Off
M916529-YYY0A
LEVER HANDLE
A918657-0070A
HANDLE SCREW
ot
H
M907024-YYY2A
INDEX BUTTON (ARROW)
M909732-YYY0A
SPOUT ESCUTCHEON
M950226-YYY0A
DIVERTER SPOUT
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
Product names listed herein are trademarks of American Standard Inc.
M968834 REV 1.3
©
AS America, Inc. 2008
|