HEPA AIR FILTRATION SYSTEMS  
Congratulations! You will quickly realize that you have purchased the  
most effective air cleaning and treatment system available anywhere. It incorpo-  
rates “state of the art” HEPA (High Efficiency Particulate Arrestance) technology.  
This is the equipment that respiratory specialists recommend.  
Your AMAIRCARE Air Filtration System comes with a limited warranty.  
With proper attention to its care and maintenance, you will receive a lifetime opti-  
mum performance.  
If your indoor air has abnormally high concentrations of particulate,  
odors or toxins, the life span of the filter media may be shortened. Excessive par-  
ticulate in the air will reduce the expected life of the HEPA filter as it will ultimately  
restrict the flow of air through the unit. Under normal conditions the HEPA filter will  
last from two to five years, and its ability to remove very small particulate actually  
improves with use. The activated carbon media has a finite limit as to the amount  
of odor or other gaseous toxins that it can absorb. Again, the higher the concen-  
trations, the shorter the expected life. Normally, the first stage pre-filter should be  
cleaned monthly and replaced quarterly.  
As indicated above, the HEPA filter’s particulate removal efficiency  
improves with use. However, the air flow through the HEPA filter media will ulti-  
mately begin to decrease, thus lowering its ability to circulate and clean as much  
air as when it was new. If the air flow through your unit is noticeably reduced, you  
can inspect the HEPA filter by removing it and seeing if the filter paper is darkened  
on the inlet or outer side. If it is, the filter cartridge should be replaced.  
Please contact your local Amaircare dealer or call Americair  
Corporation Customer Service Department at (905) 565-9488 regarding replace-  
ment of filter media, warranty information or if you have any questions or con-  
cerns about the performance of your AMAIRCARE Air Filtration System.  
 
OPERATING INSRUCTIONS  
With proper care and maintenance, you will enjoy many years of service  
and dramatically improve the quality of your indoor air. The AMAIRCARE HEPA Air  
Filtration System is designed to operate continuously and the unit should be left in  
operation at all times.  
INSTRUCTIONS  
1. The unit may be operated in a wide variety of situations. Contact your HVAC  
contractor for specific instructions.  
2. Plug the unit into a grounded outlet (120 Volt, 60 Hz or 230 Volt 50/60 Hz).  
3. Turn the unit on by rotating the control dial clockwise until you hear or feel it  
click (Some 4000V and 5000V models only have an on off switch).  
4. The unit will come on in the “HIGH” position. To Reduce the air flow, continue  
to rotate the control dial clockwise.  
5. To turn the unit off, rotate the dial counter-clockwise past the “HIGH” position  
until you hear or feel it click.  
CAUTION!  
1. Make sure that the line cord is not in the path of people walking or where any-  
thing can be rolled over it.  
2. The unit should be leveled after installation by adjusting the leveler feet.  
3. Locate the unit such that there is no possibility of moisture dripping on it.  
Moisture could leak into the unit and damage the filter or electrical components.  
4. The Air Filtration System discharges clean air through the duct connection on  
the top of the unit at the back.  
5. Before removing the door of the blower/motor section, disconnect the power  
cord.  
NOTE: You may notice a slight “new” smell from the Air Filtration System when you  
first turn it on. This is normal and harmless and it will dissipate within a few days.  
 
FILTER REPLACEMENT INSTRUCTIONS  
The AMAIRCARE HEPA Air Filtration System is designed to run continuous-  
ly. To ensure optimal performance, please carefully follow the Product  
Information and Owner’s Manual Instructions.  
FILTER REPLACEMENT INSTRUCIONS:  
1. Read these instructions completely.  
2. Unplug your unit from the power supply outlet.  
3. Open the front door of the unit to gain access to the filter compartment.  
4. Lift the rod that holds the filter in place and remove the metal plate covering  
the end of the filter.  
5. Remove the HEPA cartridges from the unit. NOTE: The carbon pre-filter and the  
HEPA filter will contain contaminants. Remove them slowly from the unit in order  
to avoid dusting.  
6. To change the first-stage carbon filter, peel off the black pre-filter that sur-  
rounds the HEPA cartridge and discard into a plastic waste bag.  
7. Wrap the new pre-filter around the HEPA cartridge completely enclosing it with  
the carbon blanket. Then peel off the paper backing of the adhesive strip on the  
inside of the pre-filter and overlay the adhesive strip on the filter to seal it tightly.  
The inner blanket (third stage filter) can be changed similarly however there is no  
adhesive strip needed to hold it in place.  
8. Replace the HEPA cartridge complete with the new pre-filter and inner blanket  
(if changed) into the casing, making sure it is seated in the ring at the back of the  
unit. Install the cover plate and the filter retaining rods.  
9. After all of the filters have been replaced, replace the front door.  
10. Plug in the unit and turn it on. For optimum performance set the unit to the  
highest speed setting.  
 
FILTER MEDIA  
There are three stages of filtration in the AMAIRCARE Air Filtration System.  
Air is drawn into the top of the unit through the duct opening above the front  
compartment and is exhausted through the duct opening above the rear fan  
compartment. The three stages of filtration are as follows:  
STAGE 1: As air enters the air treatment system it first passes through 3/16” thick  
activated carbon impregnated non-woven polyester pre-filter. This first stage of fil-  
tration removes the larger particles of dust and adsorbs[JPS1]* gaseous contami-  
nants.  
STAGE 2: After passing through the pre-filter, the air then moves through a high  
efficiency particulate removal filter. The “HEPA” (High Efficiency Particulate  
Arrestance) filter media is laser tested to remove 99.97% of the particles in the air  
stream down to a size of 0.3 microns. Particles of concern which are normally in  
this size range include pollen, household dust, cigarette smoke, bacteria, animal  
dander, molds, etc.  
STAGE 3: The clean air stream then passes through a 1/2” inner blanket of activat-  
ed carbon impregnated non-woven polyester filter material. This final stage of fil-  
tering adsorbs additional gaseous contaminants such as odors and toxic fumes.  
SERVICE LIFE  
The useful service life of the filter media in the AMAIRCARE Air Filtration  
System is directly related to the volume of air passed through the system and the  
amount of contaminants in the air. In a typical residential application, the Stage 1  
and Stage 3 filter media should be replaced every three to six months. The Stage  
2 HEPA filter should retain peak performance for a period of two to five years,  
again, depending on the amount of particulate in the air and the maintenance  
of the Stage 1 pre-filter.  
 
AMERICAIR CORPORATION - PARTS LIST  
The following are the item numbers for the various filter replacement components  
needed to ensure long-term optimum performance from your AMAIRCARE HEPA  
Air Filtration System. To order, please contact your Dealer directly or call the fac-  
tory to obtain the name of the Dealer nearest to your location.  
PART NUMBER  
90005406  
DESCRIPTION  
16” HEPA Filter Cartridge (100 sq. ft.) 4000V / 6500 / 8500  
16”HEPA Filter Cartridge (125 sq. ft.) 5000V / 1000  
90005506  
9100540608  
Complete HEPA Filter Replacement Kit 4000V  
(Includes Pre-filter, 100 sq. ft. HEPA filter and Inner Blanket.)  
9100550608  
9100640608  
9100650608  
Complete HEPA Filter Replacement Kit 5000V  
(Includes Pre-filter, 125 sq. ft. HEPA filter and Inner Blanket.)  
Complete HEPA Filter Replacement Kit 6500/8500  
(Includes 3 Pre-filters, 3 16” 100 sq. ft. HEPA filters and 3 Inner Blankets.)  
Complete HEPA Filter Replacement Kit 10000  
(Includes 3 Pre-filters, 3 125 sq. ft. HEPA filters and 3 Inner Blankets.)  
92005-11  
93005-21  
94006021  
16” Activated Carbon Pre-filter  
16” Activated Carbon Inner Blanket  
Annual Activated Carbon Replacement Kit  
MODELS 6500, 8500 and 10000 (Includes 6 pre-filters and 3 inner blankets)  
94005011  
95005-6  
Annual Activated Carbon Replacement Kit  
MODELS 4000V and 5000V (Includes 4 pre-filters and 2 inner blankets)  
16” VOC Canister  
*** IF YOU ARE NOT SURE WHICH HEPA CARTRIDGE YOU NEED PLEASE SPECIFY THE  
SERIAL NUMBER OF YOUR SYSTEM WHEN ORDERING.  
***MODELS 6500, 8500, AND 10000 HAVE 3 HEPA CARTRIDGES PER SYSTEM  
***MODELS 4000V AND 5000V HAVE 1 HEPA CARTRIDGE PER SYSTEM  
 
SPECIFICATIONS  
The Amaircare Models 4000V, 5000V, 6500, 8500, and 10000 HEPA Air  
Filtration Systems are designed for indoor air quality improvement situations where  
high capacity is required. Following are the specifications for these five models:  
MODEL 4000V HEPA AIR FILTRATION SYSTEM  
Capacity:  
Air Flow - 50 cubic feet - 300 cubic feet/max.  
Maximum hourly flow - 18,000 cubic feet  
Recommended service area - 700 sq. ft.  
Maximum Power Consumption:* 120 watts (1 motor)  
MODEL 5000V HEPA AIR FILTRATION SYSTEM  
Capacity:  
Air Flow - 100 cubic feet - 450 cubic feet/max.  
Maximum hourly flow - 27,000 cubic feet  
Recommended service area - 1000 sq. ft.  
Maximum Power Consumption: 160 watts (1 motor)  
MODEL 6500V HEPA AIR FILTRATION SYSTEM  
Capacity:  
Air Flow - 150 cubic feet - 650 cubic feet/max.  
Maximum hourly flow - 39,000 cubic feet  
Recommended service area - 1500 sq. ft.  
Maximum Power Consumption: 250 watts (3 motor)  
MODEL 8500 HEPA AIR FILTRATION SYSTEM  
Capacity:  
Air Flow - 200 cubic feet - 850 feet/max.  
Maximum hourly flow - 51,000 cubic feet  
Recommended service area - 1,500 sq. ft.  
Maximum Power Consumption: 360 watts (3 motor)  
MODEL 10000 HEPA AIR FILTRATION SYSTEM  
Capacity:  
Air Flow - 250 cubic feet - 1000 cubic feet/max.  
Maximum hourly flow - 60,000 cubic feet  
Recommended service area - 2,500 sq. ft.  
Maximum Power Consumption: 600 watts (3 motor)  
Manufactured by:  
AMERICAIR CORPORATION  
770 Gana Court  
Mississauga, Ontario, Canada L5S 1P1  
Tel: (905) 565-9488 Fax: (905) 565-9866  
* Motors/Blowers: All motors used are thermally protected class “B” insulated motors and are designed for  
continuous operation. Service: 120 Volt, 60 Hz or 230 Volt, 50/60 Hz  
 

Abbingdon Music Research CD Player CD 77 User Manual
ACTiSYS Network Card ACT IR100S User Manual
Aiphone Home Security System AI RS150 User Manual
Aiwa Stereo Receiver AV DV500 User Manual
Alliance Laundry Systems Washer F232148 User Manual
Allied Telesis Switch AT 8948 User Manual
Atmel Computer Hardware 8 16 bit High Performance Low Power Flash Microcontrollers User Manual
Axis Communications Home Security System T90C10 User Manual
BC Speakers Portable Speaker ME45 User Manual
Behringer Music Pedal US600 User Manual