Altinex Stereo Amplifier DAA0106 V0A2 User Manual

DISTRIBUTION AMPLIFIERS  
MANUAL PART NUMBER: 400-0078-003  
PRODUCT REVISION: 1  
DAA0106-V0A2  
1-IN, 6-OUT AUDIO  
DISTRIBUTION AMPLIFIER  
USER’S GUIDE  
 
DISTRIBUTION AMPLIFIERS  
· Handle the  
DAA0106-V0A2  
Amplifier carefully because dropping or jarring  
can damage internal components.  
Distribution  
PRECAUTIONS / SAFETY WARNINGS  
1
Please read this manual carefully before using your  
DAA0106-V0A2 Distribution Amplifier. Keep this  
manual handy for future reference. These safety  
instructions are to ensure the long life of your  
DAA0106-V0A2 and to prevent fire and shock  
hazard. Please read them carefully and heed all  
warnings.  
· Do not place heavy objects on top of the  
DAA0106-V0A2. If the is to be mounted to a  
table or wall, use only Altinex made mounting  
accessories, such as rack mount shelf  
(DA1293FC, DA1294FC) and cables for  
optimum setup.  
· To turn off the main power, be sure to remove  
the cord from the power outlet. The power  
outlet socket should be installed as close to the  
equipment as possible, and should be easily  
accessible.  
1.1 GENERAL  
· Unauthorized personnel shall not open the unit  
since there are high-voltage components  
inside.  
· Qualified Altinex service personnel, or their  
authorized representatives must perform all  
service.  
· Do not pull the power cord or any cable that is  
attached to the DAA0106-V0A2 Distribution  
Amplifier.  
· If the DAA0106-V0A2 Distribution Amplifier is  
not used for an extended period, disconnect the  
power cord from the power outlet.  
1.2 SAFETY GUIDELINES FOR THE RACK-  
MOUNTING OF THE DAA0106-V0A2  
· Maximum operating ambient temperature is 35  
1.4 CLEANING  
(degrees C).  
· Never restrict the air flow through the devices’  
· Unplug the DAA0106-V0A2 power cord before  
cleaning. Clean surfaces with a dry cloth. Never  
use strong detergents or solvents, such as  
alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
fan or vents.  
· When installing equipment into  
a
rack,  
distribute the units evenly. Otherwise,  
hazardous conditions may be created by an  
uneven weight distribution.  
1.5 FCC / CE NOTICE  
· Connect the unit to a properly rated supply  
· This device complies with part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
circuit.  
· Reliable Earthing (Grounding) of Rack-Mounted  
Equipment should be maintained.  
1.3 INSTALLATION  
· For best results, place the DAA0106-V0A2  
Distribution Amplifier on a flat, leveled surface  
in a dry area away from dust and moisture.  
· This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide  
· To prevent fire or shock, do not expose this unit  
to rain or moisture. Do not place the  
DAA0106-V0A2 Distribution Amplifier in direct  
sunlight, near heaters or heat radiating  
appliances, or near any liquid. Exposure to  
direct sunlight, smoke, or steam can harm  
internal components.  
reasonable  
protection  
against  
harmful  
interference when the equipment is operated in  
a commercial environment. This equipment  
generates, uses, and can radiate radio  
frequency energy and, if not installed and used  
in accordance with the instruction manual, may  
2
 
DISTRIBUTION AMPLIFIERS  
cause  
harmful  
interference  
to  
radio  
MECHANICAL  
Audio  
communications. Operation of this equipment  
in a residential area is likely to cause harmful  
interference in which case the user will be  
required to correct the interference at his own  
expense.  
Material  
Finish  
Top Panel  
0.1” Al  
Gray  
Lexan  
Height (inches)  
Width (inches)  
Depth (inches)  
Weight (pounds)  
Ship Weight (pounds)  
T° Operating  
T° Maximum  
Humidity  
1.75in (44mm)  
8.50in (216mm)  
4.93in (125mm)  
2.0lbs. (0.91kg)  
4.0lbs. (1.81kg)  
10°C-35°C  
· Any changes or modifications to the unit not  
expressly approved by Altinex, Inc. could void  
the user’s authority to operate the equipment.  
50°C  
ABOUT YOUR DISTRIBUTION AMPLIFIER 2  
50% non-condensing  
MTBF (calculations)  
40,000 hrs  
The DAA0106-V0A2 is a product of exceptional  
quality and design, which includes stereo audio  
amplifiers.  
Table 2. DAA0106-V0A2 Mechanical  
ELECTRICAL  
Input Signals  
Level  
Audio  
The audio amplifier is designed to provide six  
buffered and amplified outputs for both left and  
right channels. The input signals are isolated to  
prevent ground loops. The input termination is  
switch selectable to either be 600 Ohms or high  
impedance.  
10 V p-p max  
600 Ohms or high  
impedance  
Differential input  
isolated from GND  
Impedance  
Type  
Output Signals  
Level  
Impedance  
Type  
The DAA0106-V0A2 Distribution Amplifier is a  
state-of-the-art product with a bandwidth of 10Hz to  
20kHz for audio signals.  
10V p-p  
Low – drives 600 Ohms  
Differential input  
isolated from GND  
0 dB unbalanced, +6dB  
balanced  
Gain  
TECHNICAL SPECIFICATIONS  
3
Frequency Compatibility  
Typical Bandwidth  
Power  
FEATURES/DESCRIPTION  
GENERAL  
Audio  
10Hz – 20kHz  
1
No. of Inputs  
Input Connector  
Internal Power Supply  
90-140V/  
200-240V  
10 watts max  
One 3.5 mm 5-pin  
Terminal Block  
6
Six 3.5mm Terminal  
Blocks  
Power Consumption  
No. of Outputs  
Output Connector  
Table 3. DAA0106-V0A2 Electrical  
Stereo or Mono Audio  
Compatibility  
Table 1. DAA0106-V0A2 General  
3
 
DISTRIBUTION AMPLIFIERS  
DESCRIPTION OF DAA0106-V0A2  
4
4
 
DISTRIBUTION AMPLIFIERS  
APPLICATION DIAGRAM  
5
5
 
DISTRIBUTION AMPLIFIERS  
INSTALLING YOUR DISTRIBUTION  
AMPLIFIER  
OPERATION  
7
6
The DAA0106-V0A2 will operate successfully as  
long as cables are attached properly and other  
technical specifications are followed.  
Step 1. Connect the power cord to the unit and  
plug it into the power outlet. The power  
indicator LED on the front panel will light.  
This indicates that the unit is operational.  
7.1 TERMINATION SWITCH  
The termination switch of the audio amplifier may  
be set to 600 Ohms on the audio input if it is in the  
ON position, and high impedance in the OFF  
position.  
Step 2. Connect the audio output of the source  
(computer, VCR, etc.) to the input of the  
DAA0106-V0A2 using high quality cables.  
The LED on the front panel will turn  
green. This indicates an input signal on  
the input of the distribution amplifier.  
Step 3. Connect the output channels of the  
amplifier to the display devices, such as  
monitors or projectors.  
Step 4. Verify that the quality of the output signal  
on all speakers is good. If the quality of  
the output signal is less than perfect,  
make sure that high quality cables are  
used, and all connections are solid.  
CONGRATULATIONS! YOU ARE DONE.  
If you experience any problems, please call  
1-800-258-4623 or 1-714-990-2300 for  
international calls.  
6
 
DISTRIBUTION AMPLIFIERS  
ACCESSORIES  
Model No.  
8
FREQUENTLY ASKED QUESTIONS  
9
No: Question Answer  
Description  
1
What is a  
Distribution  
Amplifier?  
A Distribution Amplifier is a  
device that allows you to  
connect a single signal  
source to multiple display  
devices, such as monitors  
or projectors used in  
TABLE MOUNT BRACKETS  
1 U High, ½ Rack-Wide  
1 U High, ½ Rack-Wide with 15-pin  
HD connector plate  
1 U High, ½ Rack-Wide with SNAP-  
IN connectors  
TM1271  
TM1272  
TM1273  
TM1274  
1 U High, ½ Rack-Wide with SNAP-  
IN and power connectors  
RACK MOUNTING BRACKETS  
19” - 1U Rack Mount Shelf (for  
tandem 2- Units)  
19”- 1U Rack Mount Ears for  
single unit  
HIGH RESOLUTION MULTI-  
CHANNEL COAX CABLE  
length XX = 3, 6, 12, 25, 50, 75,  
100, 150 feet  
presentation applications.  
When do I use In some cases, you need a  
2
3
connection of an audio  
source to as many as six  
different audio amplifiers.  
The DAA0106-V0A2 can  
pass mono or stereo audio  
signals.  
the DAA0106-  
V0A2?  
DA1293FC  
DA1294FC  
Which signal  
format can be  
passed  
through the  
DAA0106-  
V0A2?  
4
What if I do  
not use all of  
the outputs?  
All of the outputs are  
4 BNC to 4 BNC  
5 BNC to 5 BNC  
SUPER HIGH RESOLUTION  
MULTI-CHANNEL COAX CABLE  
length XX = 3, 6, 12, 25, 50, 75,  
100, 150 feet  
CB41XXMR  
CB42XXMR  
completely independent,  
and it is not necessary to  
terminate unused outputs.  
4 BNC to 4 BNC  
5 BNC to 5 BNC  
CB43XXMR  
CB44XXMR  
PLENUM-FLEX MULTI-CHANNEL  
COAX CABLE  
length XXX = 3, 6, 12, 25, 50, 75,  
100, 150, 200, 250 feet  
5 BNC to 5 BNC, high resolution  
coax cable  
5 BNC to 5 BNC, super high  
resolution coax cable  
CB5000PL-  
5BM0XXX5BM  
CB5100PL-  
5BM0XXX5BM  
POWER CABLES  
Power cable for US  
PC5301US  
PS5302UK  
PS5303AU  
PS5304GR  
Power cable for England  
Power cable for Australia  
Power cable for Germany  
7
 
DISTRIBUTION AMPLIFIERS  
If the product has been opened, the restocking  
fees will apply. For the restocking fee amount,  
please contact an Altinex Sales Representative.  
TROUBLESHOOTING GUIDE  
10  
· Please make sure that the audio voltage level is  
less than 10V p-p.  
If the product is in your possession for more than  
30 days, the restocking fees will also apply.  
· Make sure to use the correct power cable with  
the appropriate connector for the country in  
which it is being used.  
Altinex will not accept any returns on cables or  
custom products.  
· If a problem arises after continuous usage at  
higher voltage, higher temperature, higher  
humidity, or at other extreme environmental  
conditions, please correct the problem.  
If your product is in warranty and needs service,  
contact the Altinex Sales Department for an RMA  
(Return Material Authorization). Products returned  
without an RMA number may experience a delay  
in service.  
ALTINEX POLICY  
11  
If your product is out of warranty and needs  
service, contact the Altinex Sales Department for  
an RMA (Return Material Authorization). Products  
returned without an RMA number may experience  
a delay in service. The service charges will be  
quoted to you before the actual repairs are done.  
11.1 LIMITED WARRANTY  
Altinex warrants that its products and cables are  
free from defects in materials under normal use  
and service. This warranty is limited to repairing at  
company’s factory any part or parts of the product,  
which upon company’s examination shall disclose  
to be, thus defective. Products shall be returned to  
the company with transportation charges pre-paid  
within 2 years (90 days for cables) from date of  
shipment to the purchaser. The warranty is  
expressly instead of all other warranties  
expressed or implied. Altinex neither assumes nor  
authorizes any other person to assume for it any  
other liability in connection with the sale of the  
products. This warranty shall not apply to any  
product that has been repaired or altered outside  
of company’s factory in any way so as, in its  
judgment, to affect its stability or reliability, or that  
has been subject to misuse, negligence or  
accident.  
11.3 CONTACT INFORMATION  
Sales Department  
Phone:  
Fax:  
714-990-2300  
714-990-3303  
Accounting Department  
Phone:  
Fax:  
714-990-6088  
714-990-5778  
11.2 RETURN POLICY  
It is very important to Altinex that you receive the  
products that you have ordered and that this  
product fulfills your need. In the unlikely event that  
an Altinex product needs to be returned please  
follow the policy below:  
Altinex will accept product returns for a period of  
30 days from authorized Altinex dealers. Products  
should be returned in an unopened package.  
8
 

3M Computer Monitor 11 71315 225 01 User Manual
Acer Projector P5271n User Manual
ADC Switch ProAx User Manual
AEG Freezer A62000GNW0 User Manual
Allied Air Enterprises GPS Receiver KLN 90B User Manual
Atmel Network Card ATA6602 User Manual
Audiovox Car Stereo System ACC 50A User Manual
Axis Communications Printer 540+ User Manual
Axor Plumbing Product 06046XX0 User Manual
BK Stereo Amplifier 5 S2 User Manual