AllerAir Advantage
All metal housing to avoid plastic off-gasing
Totally innert gaskets. No use of rubber or neoprene
Separate carbon and HEPA filters for easier,
less costly maintenance
No ozone emissions
Our Famous Gurantee
More filtration.
More features.
Better value.
Call our indoor air quality experts
1-888-852-8247
Model Air Medic
or
Visit our website:
For more information
Operation and Maintenance Manual
AllerAir Industries Inc.
AllerAir_Mk:Manuals:Manual_AirMedic/October 31 2005
ALLERAIR'S AIR PURIFICATION SYSTEM
FILTER ASSEMBLY- Air Medic D
D Models have a 3" deep carbon filter.
LASER TESTED TRUE HEPA
HEPA (Hight Efficiency Particulate Arrestance) filters were develped for the Atomic
Energy Commission to remove radio active dust from their laboratories. The are now the
primary filtration systems for electonic clean room assembly, hospital surgeries, bio
engineering, pharmaceutical laboratories and any other space where clean air is critical.
HEPA will trap microscopic dust which will give you distress from allergies, asthma,
respiratory problems, chemical sensitivities and sick building syndrome. It will trap
99.97% of all particles down to 0.3 microns (including bacteria, dust mite antigens,
respiratory particles, fungal and other microbiologicals. For these reasons that HEPA
filtration is recommended by more allergists, medical professionals and clean air
consultants than any other filter system available.
CARBON FILTER (ACTIVATED AND GRANULATED)
We use only activated granular carbon mixed with zeolite and specially impregnated
carbons. We stay away from dust carbon which has been impregnated onto a poly or
foam material. This type of carbon filter has to be changed as often as every week to be
fully effective. AllerAir's carbon filter can last up to 2 or 3 years and more, depending on
the level of toxins in the area.
Step 1
Turn Power Off and
unplug receptacle.
Step 3
Gently grasp wheels.
Step 2
With a #2 Philips screw driver,
remove the four screws from the
bottom of the unit.
Remove base by gently pulling on
the wheels.
Lay unit upside down.
The activated carbon we use is derived from coconut shell and can adsorb up to 60% of
its own weight in toxic gases, fumes and chemicals. These toxic substances make us ill,
and are found in every home, office and industry.
OTHER FILTERING SYSTEMS AVAILABLE
Ozone generators, negative ion machines and electrostatically charged units all
generate ozone which is a toxic substance. Any unit which provides ozone cannot be
recommended by Health and Welfare or by the Lung Association.
AllerAir's units on the other hand do not produce any ozone whatsoever. The latest air
purification technology does not add anything to the air (especially impurities like
ozone or P.V.C.s). AllerAir's unit scrubs impurities and toxins out of the air.
ENERGY COSTS
We use a high efficiency motor which cost pennies a day to operate in contrast to
almost all other manufactures who use the lowest price motor available. One of the
reasons we can offer a five year extendible to ten year warranty is because of the
sophisticated motor we use. We have spared no effort to give you the most for the least.
Step 4
Step 5
Step 6
Replace the gasket that had been
removed in STEP 4.
Remove only one of the white, felt,
donut-shaped gaskets from the
inside of the purifier body.
Insert the carbon filter (either a
Model 600 D Carbon or a Model 600
DX Carbon) into the unit.
ADDITIONAL INFORMATION
The rush of air on "Low", makes less noise which is often used to help people sleep more
soundly. Use "High" in work places or home living rooms. Use "Turbo" when you are out
of the area for the day or night. The sound you hear from the unit is the sound of the air
passing through the vent to achieve a current so that your complete area will receive
changes of air.
The air coming out of the unit may feel cool to your hand, but the temperture of the air
is actually the same. And AllerAir units are specially designed to have no offgasing
because our entire unit housing is made of steel.
IMPORTANT NOTICE
To receive maximum use of HEPA filter media when used in freshly painted room, you
should first remove the HEPA filter from the unit to avoid contaminating the HEPA
media. Turn unit off and Ungplug unit. Remove bottom screws. Open bottom of unit,
Grasp outer filter ring firmly with both hands and remove carefully. Close unit, plug into
grounded receptacle then turn on. Replace carbon filter before reinstalling HEPA filter.
Step 7
Step 9
Turn the unit back onto its wheels.
It is now ready for immediate use.
Place lid back to its proper position
by aligning the arrow with the rear
seam.
Step 8
Replace the four screws
Do not allow any object to be stuck or poked into any opening of the unit.
Never service the unit before turning unit off and removing electrical plug
from the wall receptacle.
The AllerAir AirMedic - Indoor Air Purification System
REPLACING FILTER ASSEMBLY- Air Medic
Congratulations, you are moments away from fresher, cleaner indoor air. Your new
AllerAir unit will combat many of the chemicals, gases, odors and particles
responsible for poor indoor air quality, and in turn, health concerns such as
allergies, asthma, sick building syndrome and multiple chemical sensitivity. As with
any air cleaner, proper maintenance of your unit is a vital part of keeping it
operating at peak efficiency.
Operation:
Your unit is shipped fully assembled and ready for use. Plug into 120V-15amp
outlet. For best results situate your unit close to your sitting, sleeping or work area.
NOTE: Please save your packaging. Original packaging will be required for all
warranty returns.
FIVE YEAR (5) LIMITED WARRANT
Step 1
Turn Power Off and
unplug receptacle.
Step 2
With a #2 Philips screw driver,
remove the four screws from the
bottom of the unit.
ALLERAIR
Step 3
Gently grasp wheels.
Warrants their home use AirMedic series units to be free from defects in materials
and workmanship under normal use and service for a period of 5 years from date
of purchase.
Lay unit upside down.
The obligation of this warranty shall be limited to repairing or replacing any part
of the unit which we agree is defective in materials or workmanship under normal
use and service during the five year period commencing with the date of
purchase, sent with the original or sufficient packaging protection.
Please call toll free 1-888-852-8247 for detailed return instructions.
This five year warranty is in lieu of all other express warranties, obligations or
liabilities (expect those implied warranties, which in some states cannot be
excluded).
Step 5
Step 6
First remove the HEPA filter by
placing thumbs on the inner side of
the filter.
Than remove the Carbon filter by
placing thumbs on the inner side of
the filter.
No agent, representative, dealer or employee of the company has the authority to
increase or alter the obligations of this warranty. This warranty shall not apply to
any unit which has been modified, repaired or altered in any way without the
express written consent of AllerAir Industries Inc. This warranty does not apply to
any expendable parts of the unit.
Step 4
Remove base by gently pulling on
the wheels.
Then pull up gently until totally out.
Then pull up gently until totally out.
In no case shall AllerAir Industries Inc. be liable for any consequential damages for
breach of this or any other warranty expressed or implied whatsoever.
This warranty is limited to the original retail purchaser and is not transferable.
Kindly address any questions regarding this warrany to AllerAir Industries Inc.
EXTENDED WARRANTY
Step 9
AllerAir's five year warranty is extendible to 10 years. Kindly call for information.
AllerAir manufactures the most effective air purification systems, using the latest
technology available today. These are distributed worldwide for commercial,
residential, institutional and industrial use. The units meet all the higest standards
required for safety and health.
Step 7
Step 8
With a screw driver, place 4
screws back into their positions.
Replace filters with new ones then
reassemble by inserting the Carbon
filter first then the HEPA filter.
Place lid back to its proper position
by aligning the arrow with the rear
seam.
Gently return the unit into
upright position.
AllerAir Industries Inc.
|