C-Band Hub-mount
SSPA/ SSPB
60W to 250W
AWMA-3000C series
Features
Remote Monitor & Control
High gain and linearity
Output power up to 250W (see table A)
Gain adjustment
Output sample monitor port
Temperature gain compensation
Automatic over-temperature shutdown
Automatic high reflected power shutdown
Infinite VSWR protection
Field replaceable power supply
CE Marking
Overview
The AWMA-C series are the outdoor solid-state power amplifiers
(SSPAs), operating in C-Band frequency range. The amplifier is an
integrated unit, complete with power supply and cooling system.
Intended for outdoor operation, the AWMA-3000C is weatherproof.
Built-in microprocessor controller provides the capability for serial
port interfaces (RS485, RS232) for remote monitoring and control.
Table A
Output
RF Band
Power
(GHz)
(W)
Band
CL
CP
CI
4.400 - 5.000
6.425 - 6.725
6.725 - 7.025
5.725 - 6.025
5.850 - 6.425
5.850 - 6.725
60 – 200
60 – 200
60 – 200
60 – 250
60 – 250
60 – 150
Advantech’s SSPAs set the industry standard for linearity and
operating efficiency. Built-in design features and assembly methods
incorporated with efficient combining techniques result in the
trouble-free operation of the amplifier.
CR
CS
CX
Application
*Other frequency sub-bands are available. Please consult
factory.
The SSPAs are designed for C-Band satellite up-link applications.
They are mounted outdoors, near the hub of an antenna. The
AWMA-C series are available in output power from 20W to 1000W.
For higher power Advantech provides phase-combined systems.
Options
Integrated Block Up Converter
Additional harmonic filter
Extreme temperature operation
Redundant system
Other SSPAs are available for operation at other satellite frequency
bands. With all the features of the AWMA-C, Advantech also offers a
built-in converter.
Redundancy
Accessories
With the addition of the appropriate waveguide and switch kit, the
AWMA-3000C amplifiers can be easily converted for the operation
in 1:1 redundant configuration with full remote Monitor and Control
capability of the redundant system via serial interface. A single
Monitor and Control interface is required to manage redundant
system.
Redundancy Kit
Mounting Frames
Remote M&C panel (Ethernet port optional)
|