ATN Binoculars MK 6600 User Manual

Aries MK 6600/6650  
Aries MK 8700/8750  
u s e r ` s g u i d e  
AMERICAN  
TECHNOLOGIES  
NETWORK  
CORP.  
 
APPLICATION  
The Aries MK6600/6650/7700/7750/8700/8750 night vision weapon scope is a complex computer-  
ized system for the observation of objects at low light levels. Containing an onboard computer these  
scopes are some of the most advanced night vision weapon scopes in the world.  
The Aries MK6600/6650/7700/7750/8700/8750 consists of the objective lens assembly, ocular  
lens assembly and the body. The body contains the image intensifier tube assembly with the inte-  
grated high voltage power source. The body also houses the electronics for the reticle, the computer  
console for the “Smart Technology” as well as the battery compartment. The 100M infra-red illumi-  
nator is located on the top of the unit.  
The objective lens protective cover (not shown) is designed to protect the lens from scratches and  
abrasions. This cover also protects the image intensifier tube from exposure to daylight or other  
bright light sources. The protective cover acts as a daylight filter, note the pinhole in the center of  
the lens cap.  
MASTER POWER SWITCH  
Master power switch  
The Master ON/OFF switch is to be found on top of  
MK6600/6650/7700/7750/8700/8750. Once the  
scope’s master power is switched on you can adjust  
the scope using the buttons on the control box.  
CONTROL PANEL  
The control box with the cluster of three buttons on it can be found on the left side of the Aries  
MK6600/6650/7700/7750/8700/8750. ”SLbutton acts as a three-way selection toggle. By press-  
ing it once you will see one of three colored diodes located on the rear side of the control box light  
up. Make sure to keep both eyes open; your right eye is expected to aim through the scope so that  
your left eye perceives the changes on the rear side of the control box. “+” and “-” buttons are used  
to correspondingly increase or decrease adjustments for a chosen function.  
The three colored led diodes represent the scope function mode. “B” stands for brightness of the  
light intensifier tube, “R”- for reticle brightness, and “I”- for IR illuminator brightness.  
“+” adjustment button  
“SLselection button  
“-” adjustment button  
Illuminator brightness LED  
Reticle brightness LED  
Brightness LED  
2
 
LIGHT INTENSIFIER TUBE BRIGHTNESS ADJUSTMENT  
The green led “B” represents the light intensifier tube power  
ratio. Once this is lit you can adjust the brightness of the light  
intensifier with the “+” and “-” adjustment buttons.  
Green LED “B”  
RETICLE BRIGHTNESS ADJUSTMENT  
By pressing the SL button twice you switch to a yellow “R”  
diode next to the green one. The yellow diode represents the  
reticle’s brightness. Adjustments could be easily seen if you look  
through the Aries MK6600/6650/7700/7750/8700/8750 while  
pressing “ +” /” -” adjustment buttons.  
To adjust the brightness of the reticle or to turn it off use the con-  
trol box buttons located on the side of the unit. Press and hold “+  
“or” -” adjustment buttons while the yellow diode is on and see  
brightness changes looking through the scope. After appropriate  
level of brightness has been set release the button.  
Yellow LED “R”  
INFRA-RED ILLUMINATION  
By pressing “SLbutton three times you can switch to Red diode  
“I”. Red diode represents 100M infra-red illuminator’s bright-  
ness adjustment mode. Adjustments can be easily observed  
through the Aries scope while pressing” +” /” -” adjustment but-  
tons.  
Infra-red illuminators, or IR illuminators, are common to night  
vision. The IR light greatly enhances to the performance of the  
Aries MK6600/6650/7700/7750/8700/8750 while remaining  
almost totally invisible to the unaided eye.  
Power up the Aries scope in a dark environment. Find an object  
and examine it with IR off, then on. You could observe illumina-  
tion difference. It is important to remember that the IR illuminator  
is simply an infra-red light source and like any light source it may  
loose its effectiveness over long distances.  
To change the field of coverage from the IR illuminator, focus  
the beam by turning IR illuminator lens to slightly alter the beam  
width.  
Red LED “I”  
3
 
SLEEP MODE  
One of the greatest new features that your Smart scope has is the SLEEP mode. This feature has  
been designed to considerably extend the period of scope’s functioning, to set the scope to memo-  
rize your initial settings and endure battery’s life (by settings we mean only digital settings which  
include brightness of the tube, brightness of the reticle, and magnitude of the IR.) Here is a descrip-  
tion as to now the sleep mode functions:  
The scope will automatically shut down if it does not sense any activity (i.e. pressing any of the but-  
tons or simply moving the scope back and forth away from your face) for 20 minutes. When activat-  
ing the sleep mode the scope will first warn you by turning off the reticle for 10 seconds. If you intend  
is to keep using the scope simply touch any key and the scope will reactivate.  
One of the reasons for the SLEEP mode being programmed into your scope is to keep the light  
intensifier tube and batteries safe in case you forget to turn your unit off. If you notice that the reticle  
turned off after 20 minutes just push the SL button and the scope will return to its previous settings.  
To put your scope in the “SLEEP” mode any time, just push the SL button and “-” simultaneously.  
Push SL to return to previous settings and the SMART scope will remember them. This feature will  
come very handy, if you are waiting for game to come: you can prepare all of the settings, place  
the unit in SLEEP mode and activate it precisely when you need it. To disable the proximity sensor  
press SL and “+” simultaneously. In order to turn the proximity sensor back on, press SL and “+”  
simultaneously again.  
NOTE: The scope is capable of running in SLEEP mode for more than 10 (ten) days and is ready for  
use at any moment. Remember, you don’t have to turn the unit off while you are using it (“Smart” sight  
remembers all the settings). Use the master ON/OFF switch only to store the scope.  
PROXIMITY SENSOR  
If you turn the proximity sensor on it will activate the  
scope when brought to your eye. The proximity sensor  
Proximity sensor  
disables the scope when you take it away from your  
face. This feature has been introduced to prolong the  
life of the tube and the battery.  
To turn the proximity sensor on press SL and + at the  
same time.  
To disable the proximity sensor press SL and + at the  
same time again.  
NOTE: Proximity sensor would not turn on automati-  
cally after master power has been switched on.  
4
 
FOCUSING  
To focus the Aries MK6600/6650/7700/7750/8700/8750 you need to adjust the diopter first thing.  
Simply turn the diopter clockwise until it stops. Then concentrate on any object and slowly turn the  
diopter back counter clockwise until the grain in the image is sharp.  
When you are under low-light conditions and the daylight filter is off you may focus the front lens for  
the image to be sharp. The diopter is not to be adjusted.  
NOTE: The front lens should be readjusted for viewing objects at different distances.  
You scope has ability to focus either long range or short. To adjust focus unlock front lens with the  
Large Allen wrench (included with scope). After focusing lens to desired distance re-lock lens in  
place to insure no movement of reticle while shooting.  
NOTE:To remove the front lens to clean, you must unlock the above set screw.  
Diopter  
Front lens  
Insert large allen wrench  
here to lock/unlock and  
to remove lens  
MOUNTING THE ARIES MK6600/6650/7700/7750/8700/8750  
1. Slightly loosen the horizontal and vertical fixing screws on the 7/8” weaver rail built into the  
MK6600/6650/7700/7750/8700/8750.  
2. Place the scope on the dovetail mount of the fire arm making certain that the mount aligns with the  
receptor attachment screw groove. Adjust as necessary.  
3. Tighten the horizontal fixing screws.  
NOTE: Receptor attachment screws may need to be tightened after continuous shooting.  
Fixator screws  
5
 
WINDAGE AND ELEVATION  
To adjust vertical and horizontal positions for the  
Aries MK6600/6650/7700/7750/8700/8750 turn the  
elevation and windage adjustment mechanisms. Each  
click equals to 1/8 inch at 100 yards. Do not use force  
having reached the maximum of rotation.  
Windage  
Elevation  
USING THE REMOTE CONTROL  
Below the control box you can find the panel with two  
screws to fix Aries MK6600/6650/7700/7750/8700/  
8750.  
To plug in the remote control, remove the screws and the  
small panel to disclose the inlet.  
The three remote control buttons’ function similarly to  
control box buttons. Once the remote control is plugged in  
you may use both panels to adjust the scope.  
The remote control can be attached to the weapon of your  
choice through whatever means best suiting your shoot-  
ing style and grip. We suggest an elastic Velcro® loop  
fastener similar to the trigger switches found on the weapon mounted laser pointers.  
RANGE FINDER  
If a 6` target fits between  
these two lines then the  
target is 300 yards away  
The range finder reticle in your Aries MK6600/7700/  
8700 has been designed to assist you in determining  
the range of your target. These distances are based  
on a 6’ target. A 6’ target fits between the numbered  
baseline (the three short horizontal lines just next to  
the numbers) and the main horizontal line. If the 6’  
target fits between the 1 and the right horizontal posts  
of the main line the target is 100 yards away. If the  
same target fits between the 2 and the right post of the  
main line the target is 200 yards away. The same is  
with the three, the target is 300 yards away.  
3
2
1
If a 6` target fits between  
these two lines then the  
target is 100 yards away  
If the “Red on Green” reticule is not perpendicular to  
the bore of the rifle, it can be adjusted by doing the  
following:  
1. Unscrew the cover between the windage and eleva-  
tion adjustments.  
2. Loosen the flat-head screw about 1/2 - 3/4 of a turn.  
3. Rotate the central threaded shaft with two notches  
as needed (make sure that you do not rotate the round  
plate mounted on this shaft individually. They will  
rotate together, but if you move the plate itself, if will  
interfere with the focus of the reticule).  
3
2
1
6
 
RETICLE PATTERNS  
The Aries MK6650/7750/8750 scopes comes  
with five reticle patterns:  
Aries  
MK6650  
MK7750  
MK8750  
• Dot  
• Post  
• Post with Dot  
• Open Cross Hair  
• Cross Hair  
You can choose your preferred pattern by  
pushing the Reticle Pattern Selector button.  
Reticle Pattern  
Selector button  
1 MOA  
1 MOA  
60 MOA  
6 MOA  
2 MOA  
60 MOA  
6 MOA  
Dot  
1 MOA  
Post  
60 MOA  
Open Cross Hair  
60 MOA  
Cross Hair  
Pos1t wMOitAh Dot  
PREPARATION FOR OPERATION  
Before getting started make sure to follow these steps:  
• Take the scope out of the case.  
• Insert the batteries into their housing with the polarity order shown on the main body of the unit.  
• Switch on your MK6600/6650/7700/7750/8700/8750 scope by the master power switch, make  
sure the protective lens cover is still attached to the lens.  
• We expect your right eye to aim through the scope. Keep both of your eyes open so you are able  
to see the color-coded LEDs with your left eye.  
• In order to assure the proper functioning of the proximity sensor make certain that the protective  
glass surface of the sensor is always clean.  
• When the scope is first powered up the initial settings are:  
- Light intensifier tube brightness -100%  
- Reticle brightness -100%  
- Illuminator brightness -100%.  
• Observe the scene and adjust the diopter for optimal image clarity.  
• You may now enter the dark environment or simply shut the lights off in order to darken the room.  
• Remove the lens cap/daylight filter.  
• Observe the scene and adjust the front lens for ideal focus.  
• Adjust the digital features as needed.  
• To increase the battery life the LED diodes go off after 10 seconds.  
• You will need to focus for different distances.  
• Take your time to learn about your “Smart” scope. It will take practice to properly use this device.  
As you use this scope you will be able to improve your speed of focusing, as well as sharpness of  
image.  
• Have fun and enjoy.  
7
 
CLEANING THE EYEPIECE  
You may need to clean the eyepiece of the riflescope from time to time in order to guarantee top per-  
formance. When you receive your riflescope you should check for dust on the eyepiece of the unit.  
First you will need to remove the eyepiece. To do that you will need to initially loosen the 2 set screws  
that can be found on the base. Then unscrew the eyepiece counter-clockwise to remove it.  
NOTE: You do not have to remove the set screws completely, they are very small and easy to mis-  
place.  
CAUTION: Use only Photographic lens cleaning tissue on these surfaces. Be careful not to scratch  
or smudge any of these surfaces. When using compressed air to blow dust away, make sure to avoid  
inverting the can while spraying. This can cause frozen propellant to exit the can, which can cause  
serious problems with the glass and phosphor screen.  
WARNINGS AND CAUTIONS  
• Always remember to turn off the Aries MK6600/6650/7700/7750/8700/8750 when it is not in use.  
If you do not plan on using your aries scope for a period of more than 10 days, you should remove  
the batteries.  
• Keep lens cap/daylight filter on when not in use.  
• Avoid contact with dust, steam, and gas.  
• The Aries MK6600/6650/7700/7750/8700/8750 are not harmful to the user or the environment.  
• Do not disassemble except to clean the front lens and the eyepiece: it will void your warranty.  
• Evaluate the scopes function by looking through it in a lit environment with the daylight filter lens  
cap on. Never use in daylight without the daylight filter lens cap on. Do not surpass ten minutes of  
testing.  
• Never point the Aries MK6600/6650/7700/7750/8700/8750 at a bright light source. If the scope  
shuts off automatically after directing it at a bright light source, turn the unit off and wait 1 - 2 min-  
utes before turning the unit back on.  
• Adverse atmospheric conditions such as fog, smog, or haze and a lack of ambient light (moon or  
starlight) may diminish the effective viewing distance. All technical data for this unit was compiled  
in a controlled environment.  
TROUBLE SHOOTING  
Q: Flashes, flickers, or clicking occur while operating  
S: If it occurs within the first five minutes of inserting new batteries, it is normal and the device will  
resume normal operation soon thereafter. If it occurs for more than 10 minutes, contact your dealer  
or other authorized service representative for service instructions.  
Q: Dark spots on screen.  
S: These are cosmetic blemishes in the intensifier tube. They are a by-product of the process of  
manufacturing night vision tubes. They will not impede your viewing ability.  
Q: Image not clear.  
S: Adjust focus ring. If problem persists, increase viewing distance  
Q: Fixed-pattern noise in a honeycomb shape.  
S: Usually a cosmetic blemish characterized by a faint honeycomb-type pattern. This usually occurs  
when viewing very bright lights. Adjust the potentiometer, to reduce brightness.  
Q: A pattern of dark thin lines which look like chicken wire.  
S: Turn on illuminator, if purchased. If illuminator doesn’t brighten image, replace batteries. If  
problem persists, contact ATN for service instructions.  
8
 
FEATURES  
• Digital “Smart technology”  
• Total darkness technology  
• Internally adjustable lit reticle for windage and elevation  
• Automatic brightness control  
• Range finder  
• Built in 100m IR illuminator  
• Mounts to standard U.S. weaver  
• Recoil & flash resistant intensifiertube  
• Auto “Sleep” mode  
• Video/35mm camera adaptable  
• Superb multi-coated 6 element lens system  
• Manufactured exclusively by ATN  
• Two year warranty  
• Assembled in U.S.A.  
SPECIFICATION  
Total Darkness Technology...........Standard  
“Smart” Technology ......................Standard  
Magnification ................................4x  
Intensifier Tube .............................US 2nd Gen. (MK6600/6650)  
......................................................US 3rd Gen. (MK7700/7750)  
......................................................US 4th Gen. (MK8700/8750)  
Detection Range ...........................250 m (MK6600/6650)  
......................................................300 m (MK7700/7750)  
......................................................400 m (MK8700/8750)  
Recognition Range .......................175 m (MK6600/6650)  
......................................................225 m (MK7700/7750)  
......................................................275 m (MK8700/8750)  
Lens System .................................6 element 90 mm; F1.7  
Field of View .................................12°  
Diopter Adjustment........................±5  
Resolution ....................................34 lp/mm (MK6600/6650)  
......................................................51 lp/mm (MK7700/7750)  
......................................................64 lp/mm (MK8700/8750)  
Range of Focus ............................1.8 m to infinity  
Reticle ...........................................Red on green rangefinder  
......................................................5 reticle patterns (MK6650, MK7750, MK8750)  
Controls.........................................Digital and remote  
Power Supply ...............................Two 3 volt lithium  
Battery Life ...................................10-20 hours  
Dimensions ...................................300 mm x 110 mm x 85 mm  
Operating Temperatures ..............-40°C to +40°C  
Weight ....................................... 1.5 kg  
9
 
2 YEAR PRODUCT WARRANTY  
This product is guaranteed to be free from manufacturing defects in material and workmanship  
under normal use for a period of 2 (two) years from the date of purchase. In the event a defect that  
is covered by the foregoing warranty occurs during the applicable period stated above, ATN, at its  
option, will either repair or replace the product, and such action on the part of ATM shall be the  
full extent of ATN’s liability, and the Customer’s sole and exclusive remedy. This warranty does not  
cover a product (a) used in other than its normal and customary manner; (b) subjected to misuse;  
(c) subjected to alterations, modifications or repairs by the Customer of by any party other than ATN  
without prior written consent of ATN; (d) special order or “close-out” merchandise or merchandise  
sold “as-is” by either ATN or the ATN dealer; or (e) merchandise that has been discontinued by the  
manufacturer and either parts or replacement units are not available due to reasons beyond the  
control of ATN. ATN shall not be responsible for any defects or damage that in ATN’s opinion is  
a result from the mishandling, abuse, misuse, improper storage or improper operation, including  
use in conjunction with equipment which is electrically or mechanically incompatible with or of infe-  
rior quality to the product, as well as failure to maintain the environmental conditions specified by  
the manufacturer CUSTOMER IS HEREBY NOTIFIED THAT OPERATION OF THE EQUIPMENT  
DURING DAYLIGHT HOURS OR UNDER ANY EXCESSIVE LIGHT CONDITIONS MAY PERMA-  
NENTLY DAMAGE THE INTERNAL COMPONENTS OF THE UNIT AND SAID DAMAGE WILL  
NOT BE COVERED UNDER THIS WARRANTY. This warranty is extended only to the original pur-  
chaser. Any breach of this warranty shall be waived unless the customer notifies ATN at the address  
noted below within the applicable warranty period.  
The customer understands and agrees that except for the foregoing warranty, no other warranties  
written or oral, statutory, expressed or implied, including any implied warranty of merchantability or  
fitness for a particular purpose, shall apply to the product. All such implied warranties are hereby  
and expressly disclaimed.  
LIMITATION OF LIABILITY  
ATN will not be liable for any claims, actions, suits, proceedings, costs, expenses, damages or  
liabilities arising out of the use of this product. Operation and use of the product are the sole respon-  
sibility of the Customer. ATN’s sole undertaking is limited to providing the products and services  
outlined herein in accordance with the terms and conditions of this Agreement. The provision of  
products sold and services performed by ATN to the Customer shall not be interpreted, construed,  
or regarded, either expressly or implied, as being for the benefit of or creating any obligation toward  
any third party of legal entity outside ATN and the Customer; ATN’s obligations under this Agree-  
ment extend solely to the Customer. ATN’s liability hereunder for damages, regardless of the  
form or action, shall not exceed the fees or other charges paid to ATN by the customer or  
customer’s dealer. ATN shall not, in any event, be liable for special, indirect, incidental,  
or consequential damages, including, but not limited to, lost income, lost revenue, or lost  
profit, whether such damages were foreseeable or not at the time of purchase, and whether  
or not such damages arise out of a breach of warranty, a breach of agreement, negligence,  
strict liability or any other theory of liability.  
PRODUCT WARRANTY REGISTRATION  
In order to validate the warranty on your product, ATN must receive a completed Product War-  
ranty Registration Card for each unit. Please complete the form below and immediately mail it  
to our Service Center: ATN Corporation, 20 South Linden Ave., Suite 1 B, South San Francisco  
CA 94080. Products qualifying for warranty repair will be either repaired or replaced within 10  
business days of receipt of merchandise unless the customer is notified otherwise.  
OBTAINING WARRANTY SERVICE  
To obtain warranty service on your unit, take or send the product, postage paid, with a copy of your  
sales receipt to our service center, ATN Corporation at the address noted above. All merchandise  
must be fully insured with the correct postage; ATN will not be responsible for improper postage, or,  
missing or damaged merchandise during shipment.  
10  
 
For customer service and technical support, please contact  
American Technologies Network Corp.  
North American Office  
20 S. Linden Ave. Suite 1B, South San Francisco, CA 94080  
phone: 800-910-2862, 650-875-0130; fax: 650-875-0129  
European Office  
phone: 44(0)870-0111286, fax: 44(0) 845-3349142  
The following countries can use our  
toll free number 00 800 9102-8620  
Austria, France, Germany, Holland, Italy, Spain, Sweden, Switzerland  
©2002 ATN Corporation  
 

3D Innovations Gas Grill UE700 User Manual
ADC Network Router VAM Value Added Modules System User Manual
Adcom Home Theater System GTP 870HD User Manual
Addonics Technologies Computer Hardware ADSACF 7M User Manual
Agilent Technologies Stereo System 6632B User Manual
Agri Fab Spreader 45 03153 085 User Manual
Asus Network Card CRW 5232AS U User Manual
Avital Automobile Alarm 4308L User Manual
Axis Communications Security Camera AXIS Q6045 Mk II PTZ User Manual
Behringer Music Pedal UF300 User Manual