TRACER Monitored Protection Switch (MPS)
Quick Start Guide
61280300L1-13B
October 2003
About this Quick Start Guide...
This guide contains information for installing your TRACER MPS system. ADTRAN recommends that the entire TRACER link be tested on a
lab bench prior to installation in the field.
Verify the existence of an adequate microwave path for each hop or link to ensure that a point-to-point microwave system is feasible for your
particular application. Record the frequency of your microwave system (2.4 GHz or 5.8 GHz) and be sure to configure the Frequency Band
menu option appropriately before operating your TRACER MPS. For more details, refer to Reviewing the Menus on page 4.
Before you begin...
ꢀ Required Components
• (2) TRACER Baseband Processor (BBP) and RF Converter (RFC) rackmount units
Or,
• (2) TRACER 4103 or 4203 integrated rackmount radio units
• RS-232 interface cable and VT100 terminal (or a PC with VT100 emulator software) for connecting to the unit
• (2) RS-232 (MALE) to RJ-45 (FEMALE) adapter (ADTRAN P/N 3196ADPT010) for creating the VT100 management chain (included in
the TRACER MPS shipment)
• (2) 8-conductor RJ-45 to RJ-45 straight-through cable for creating the VT100 management chain (included in the TRACER MPS
shipment)
• (4) Straight-through T1 cables to connect the TRACER BBP or 4103/4203 T1 interfaces to the MPS (2 are included in each TRACER
shipment)
• (2) N-Type (MALE) to SMA (MALE) cables for connecting the antenna interfaces (TRACER units) to the TRACER MPS (included in the
TRACER MPS shipment)
• 18, 20, or 22 AWG dual-conductor cable for connecting the alarm contacts between the TRACER BBP or 4103/4203 and the TRACER
MPS; also needed for connecting the MPS to an external alarm monitoring system
• Antenna, mounting hardware, and feedline cable
• 21 to 63 VDC power source (available from ADTRAN)
• (2) Straight-through T1cables to connect the TRACER MPS to other CPE equipment (included in the TRACER MPS shipment)
Or,
• (2) T1 crossover cables to connect the TRACER MPS T1 interfaces to the public-switched network (included in the TRACER MPS
shipment)
Download from Www.Somanuals.com. 1All Manuals Search And Download.
Creating the VT100 Chain
2
A single VT100 connection through the TRACER MPS provides access to both the primary (MAIN) and SECONDARY TRACER units.
Follow the steps below to create the VT100 chain.
1. Connect the RS-232 port (DB-25) on the rear panel of the MAIN TRACER BBP to the TRACER MPS VT100 interface (labeled 1 on
the figure below) using the provided DB-25 (MALE) to RJ-45 (FEMALE) adapter (P/N 3196ADPT010) and standard 8-conductor
straight-though cable. Repeat the step for the STANDBY unit (see label 2).
T1B
T1A
MANAGEMENT
MAIN UNIT VT100 Connection
1
MAIN
ALARMS
DC POWER
RF
T1B
T1A
T
R
A
C
E
R
MAIN
POWER
MODULE
OUT
IN
MAIN
TRACER
STANDBY
TRACER
STAND
BY
MONITOR
MONITOR
STANDBY
USE COPPER
CONDUCTORS ONLY
COM NC
MN COM SB
TO DTE RS-232
ANTENNA
OUT
IN
IN
OUT
B
A
B
A
2
STANDBY UNIT VT100 Connection
Connecting to the Unit
3
1. Connect a VT100 terminal (or PC with VT100 emulation software like HyperTerminal) to the TRACER MPS RS-232 console interface
using a DB-25 Male (for TRACER MPS) to DB-9 Female (for terminal or PC) straight-through serial cable.
2. Configure the COM port with the following parameters:
Data Rate: 9600
Data Bits: 8
Parity Bits: None
Stop Bits: 1
Flow Control: None
3. Open a VT100 terminal session. (Please refer to the appropriate VT100 terminal software documentation for detailed instructions.)
4. Press <Return> to begin the configuration session. The TRACER MPS Interface is now active.
Download from Www.Somanuals.com. 3All Manuals Search And Download.
Reviewing the Menus
4
The TRACER MPS software interface consists of a single menu screen (shown below). Navigate through the available menu options
using the up and down arrow keys. Alternately, the numbered menu options may be selected by entering the appropriate menu number
displayed to the left of the option. Pressing the <space bar> activates the current menu selection. The TRACER MPS VT100 interface
provides access to the MAIN and STANDBY TRACER unit menus (using menu options 1 and 2, respectively). Press <Ctrl + R> to exit the
TRACER menus and return to the TRACER MPS menu screen. A brief description of the available menu options for the TRACER MPS
follows the figure below.
Status of MAIN
TRACER system
Status of STANDBY
TRACER system
2
1
4
5
7
6
8
9
10
Navigational Help
Activates the menu system for the MAIN TRACER unit. This provides access to all configuration and status parameters.
Activates the menu system for the STANDBY TRACER unit. This provides access to all configuration and status parameters.
4
5
Configures the TRACER MPS for modem or terminal access. When connecting a VT100 terminal or PC with terminal software,
select DISABLED.To connect a modem to the TRACER MPS RS-232 interface, set this parameter to ENABLED. To disable the modem
control, press <Ctrl + Z> three times.
6
Specifies the frequency band of the MAIN and STANDBY TRACER units as 5.8 GHz or 2.4 GHz. This menu setting should match
the operational frequency of your TRACER systems, and must be manually configured by the user prior to operation.
7
Number of seconds the TRACER MPS waits (after a switch to the STANDY system) before attempting to restore MAIN operation.
8
9
Number of contiguous seconds the MAIN TRACER system must exhibit an alarm condition before the TRACER MPS switches to
STANDBY operation.
Provides instructions for navigating through the menus using the arrow keys or entering the menu number and activating the
highlighted menu by pressing the space bar.
10
Download from Www.Somanuals.com. 4All Manuals Search And Download.
5
Connecting the T1 Interfaces
1. Connect the T1A interface (RJ-45) of the MAIN TRACER BBP (labeled 1 below) to the MAIN T1A interface (RJ-45) of the TRACER
MPS (labeled 2 below) using a straight-through T1 cable (ADTRAN P/N 3127004). Follow the same procedure to connect the T1B
interfaces (labeled 3 and 4 below).
2. Repeat Step 1 to connect the T1A and T1B interfaces of the STANDBY TRACER BBP to the STANDBY T1A and T1B interfaces (RJ-
45) of the TRACER MPS (labeled 5 below).
MAIN UNIT T1B Interface
MAIN UNIT T1A Interface
1
3
T1B
T1A
MANAGEMENT
TRACER MPS
STANDBY T1A/B
Interfaces
5
MAIN
ALARMS
DC POWER
RF
T1B
T1A
T
R
A
C
E
MAIN
POWER
MODULE
OUT
IN
MAIN
RACER
TANDBY
TRACER
STAND
BY
MONITOR
MONITOR
R
STANDBY
USE COPPER
CONDUCTORS ONLY
NO COM NC
MN COM SB
TO DTE RS-232
ANTENNA
OUT
IN
IN
OUT
B
A
B
A
TRACER MPS
MAIN T1A Interface
2
TRACER MPS
MAIN T1B Interface
TRACER MPS
T1A/T1B Interfaces
4
6
3. Connect the T1A and T1B interfaces of the TRACER MPS (labeled 6 above) to the public-switched network or CPE-type equipment.
When connecting the T1A/B interfaces of the TRACER MPS to the public switched network, use a T1 crossover cable (ADTRAN P/N
3125M011). For connections to other CPE-type equipment, such as an ADTRAN TSU, use a straight-through T1 cable
(ADTRAN P/N 3127004). For your convenience, 2 (each) T1 crossover and straight-through T1 cables are provided with the TRACER
MPS shipment.
Download from Www.Somanuals.com. 5All Manuals Search And Download.
6a Connecting the Antenna Interfaces (TRACER BBP and RFC Systems)
1. Connect the Antenna interface (N-Type connector) of the MAIN TRACER RFC (labeled 1 below) to the MAIN RF interface (SMA con-
nector) of the TRACER MPS (labeled 2 below) using a male N-Type to male SMA cable.
2. Connect the IF connector on the MAIN TRACER BBP (labeled 4 below) to the IF connector on the MAIN RFC (labeled 3 below) using
the 6” RF cable (ADTRAN P/N 3125RF027).
3. Repeat Step 1 to connect the Antenna interface (N-Type connector) of the STANDBY TRACER RFC to the STANDBY RF interface
(SMA connector) of the TRACER MPS (labeled 6 below).
4. Repeat Step 2 for the STANDBY TRACER BBP and RFC.
TRACER RFC IF Interface
3
MAIN UNIT Antenna Interface
1
TRACER BBP IF Interface
4
T1B
T1A
MANAGEMENT
TRACER MPS Antenna Interface
5
MAIN
ALARMS
DC POWER
RF
T1B
T1A
T
R
A
C
E
R
MAIN
POWER
MODULE
OUT
IN
MAIN
TRACER
STANDBY
TRACER
MONITOR
MONITOR
STAND
BY
STANDBY
USE COPPER
CONDUCTORS NLY
NO COM NC
MN COM SB
TO DTE RS-232
OUT
IN
IN
OUT
B
A
B
A
TRACER MPS STANDBY
Antenna Interface
TRACER MPS MAIN
Antenna Interface
6
2
5. Connect the TRACER MPS Antenna interface (N-Type connector, labeled 5 above) to the customer provided antenna using antenna
feedline cabling. Refer to the appropriate TRACER User Manual for a detailed discussion on link planning, antenna loss/gain, and
antenna alignment.
Download from Www.Somanuals.com. 6All Manuals Search And Download.
6b Connecting the Antenna Interfaces (TRACER 4103 and 4203 Systems)
1. Connect the Antenna interface (N-Type connector) of the MAIN TRACER 4103/4203 (labeled 1 below) to the MAIN RF interface (SMA
connector) of the TRACER MPS (labeled 2 below) using a male N-Type to male SMA cable.
2. Repeat Step 1 to connect the Antenna interface (N-Type connector) of the STANDBY TRACER 4103/4203 to the STANDBY RF inter-
face (SMA connector) of the TRACER MPS (labeled 3 below).
MAIN UNIT Antenna Interface
1
T1B
T1A
TRACER MPS MAIN
Antenna Interface
2
MAIN
ALARMS
DC POWE
RF
T1B
T1A
T
R
MAIN
POWER
MODULE
OUT
IN
MAIN
TRACER
STANDBY
TRACER
A
C
E
MONITOR
MONITOR
STAND
BY
R
STANDBY
USE COPPER
CONDUCTORS ONLY
NO COM NC
MN COM SB
TO DTE RS-232
OUT
IN
IN
OUT
B
A
B
A
TRACER MPS STANDBY
Antenna Interface
3
4
MAIN UNIT Antenna Interface
3. Connect the TRACER MPS Antenna interface (N-Type connector, labeled 4 above) to the customer provided antenna using antenna
feedline cabling. Refer to the appropriate TRACER User Manual for a detailed discussion on link planning, antenna loss/gain, and
antenna alignment.
Download from Www.Somanuals.com. 7All Manuals Search And Download.
7
Connecting the Alarm Contacts
.
All alarm contact connections in the steps below should be made using standard 18 AWG insulated conductors. Insert the conductor in
the terminal block then use a flat-head screwdriver to secure the connection.
1. Connect the NO (Normally Open) alarm contact of the MAIN TRACER BBP (labeled 1 below) to the MN alarm contact in the IN alarm
block of the TRACER MPS (labeled 2 below). The TRACER BBP provides two sets of alarm contacts; for normal configuration, use
the NO located in the MAJ (Major Alarm) block.
Only the TRACER 2603 BBP provides the optional MIN (Minor Alarm) terminal block. Connecting the MIN alarm contacts allows the
TRACER MPS to perform a system switch when a minor alarm condition occurs. Please refer to the TRACER 2603 User Manual
(ADTRAN P/N 61280003L1-1) for a detailed listing of major and minor alarms.
2. Connect the COM (Common) alarm contact of the MAIN TRACER BBP (labeled 3 below) to the COM alarm contact in the IN alarm
block of the TRACER MPS (labeled 4 below). Repeat this step for the STANDBY TRACER BBP.
3. Connect the NO alarm contact of the STANDBY TRACER BBP to the SB alarm contact in the IN alarm block of the TRACER MPS
(labeled 5 below).
4. (OPTIONAL) Connect the TRACER MPS alarm contacts (NO, COM, NC) in the OUT alarm block (labeled 6 below) to your external
alarm monitoring system. Failure to follow this step will not affect TRACER MPS redundancy operation.
3
NO Alarm Contact
1
COM Alarm Contact
T1B
T1A
MANAGEMENT
Connect to
External Alarm
System
6
COM Alarm Contact
4
MAI
ALARMS
DC POWER
RF
T1B
T1A
T
R
A
C
E
R
MAIN
POWER
MODULE
OUT
IN
MAIN
TRACER
STANDBY
TRACER
STAND
BY
MONITOR
MONITOR
STANDBY
USE COPPER
CONDUCTORS ONLY
NO COM NC
MN COM SB
TO DTE RS-232
ANTENNA
OUT
IN
IN
OUT
B
A
B
A
SB Alarm Contact
2
MN Alarm Contact
5
Download from Www.Somanuals.com. 8All Manuals Search And Download.
Supplying Power to the Unit
8
9
The TRACER MPS can operate from a supply between 21 and 63 Volts DC, with either polarity referenced to ground, and consumes
3 Watts nominal, 20 Watts peak (during relay switching). Current required (in Amps) is determined by dividing the power consumed (in
Watts) by the applied voltage (in Volts). As an example at 48 Volts, the TRACER MPS would draw approximately 0.417 Amps peak (20
Watts / 48 Volts).
Pinouts
RS-232 CONSOLE INTERFACE (DB-25)
MAIN/STANDBY T1A/T1B INTERFACES (RJ-45)
Pin
Name
UNUSED
TXD
Description
Pin
Name
Description
1, 8-25
—
1
R
TRANSMIT DATA (RING)
TRANSMIT DATA (TIP)
—
2
3
4
5
6
7
TRANSMIT DATA
RECEIVE DATA
REQUEST TO SEND
CLEAR TO SEND
DATA SET READY
TERMINAL GROUND
2
T
RXD
3, 6-8
UNUSED
R1
RTS
4
5
RECEIVE DATA (RING)
RECEIVE DATA (TIP)
CTS
T1
DSR
GROUND
Download from Www.Somanuals.com. 9All Manuals Search And Download.
|